Works with the new PROTEGUS 2 app!
Trikdis E16T Ethernet universal communicator - IP module
- Brand: Trikdis
- Product Code: E16T
- Availability: Out of Stock
-
€89.90 Ex Tax: €74.92
Available Options
E16T with DSC PowerSeries Neo. Ethernet communicator setup with Protegus app.
Trikdis E16T Ethernet smart communicator can connect to any alarm panels telephone line (TIP RING) terminal for event transmission via wired Internet.
Communicator also works with Protegus 2 Android / Iphone and web app. With Protegus 2 users can control their alarm system and appliances remotely and get notifications about security system events. Communicator can transmit event notifications to the Central Monitoring Station and work with Protegus 2 simultaneously.
Communicator transmits full event information to the Central Monitoring Station.
The Trikdis E16 * and E16T communicators are excellent replacement for the Paradox IP150+ IP module and DSC ENVISA LINK4 Ethernet communicator.
What does Trikdis offer?
- Reliable operation
- Free Android, Iphone and web applications
- *Direct connection to the alarm panel - no manufacturer besides the original can do this
- Remote control (arming / disarming)
Main features:
- Ethernet, IP-based communicator
- Connects to control panel to telephone line (TIP-RING) terminals.
- When Protegus 2 service is enabled, events are first delivered to CMS, and only then are sent to app users.
- No fixed IP nor dynamic DNS is required, the messages are transmitted by the Protegus 2 server securely
Notifies users:
- Users are notified about events and can control the system via the free Protegus 2 Android / Iphone and web app
- “Push” and special sound notifications informing about events.
- Remote system Arm/Disarm using key switch zones.
Controllable outputs:
- 3 double I/O terminals that can be set either as input (IN) or controllable output (OUT) terminals.
- Outputs controlled by the Protegus 2 app.
- Add additional inputs and controllable outputs with iO expanders via RS485 port
- Remote control of connected devices (lights, gates, ventilation systems, heating, sprinklers, etc.).
Quick setup:
- Settings can be saved to file and quickly written to other communicators.
- Two access levels for configuring the device for CMS administrator and for the installer.
- Quick and easy configuration and firmware updates via USB or remotely after initial setup with Trikdis programming software.
Central monitoring station:
- Sends events to Trikdis software or hardware receivers that work with any monitoring software.
- Can send event messages to universal SIA DC-09 and SUR-GUARD TL150 receivers
- The module transmits the messages of the control panel to the monitoring station in Contact ID code format
- Connection supervision by polling to IP receiver every 30 seconds (or by user-defined period).
- Backup channel, that will be used if connection with the primary channel is lost.
- With parallel communication channels events can be sent to two receivers at the same time.
E16 Ethernet smart communicator with direct control.
Take advantage of smart features and direct control!
Alarm panels connectable via data bus or serial port
The Trikdis E16, G16, and GET can be used with all alarm panels listed below. The great benefit using the special Trikdis communicators, that events are received via the data bus or serial port.
Control panels marked red can be controlled directly from the serial port / data bus without any further wiring.
Control panels marked black means these control panels get the events from the serial port / data bus, but for remotely controlling the alarm system, key-switch zones and additional wiring is required
Serial port
Spectra SP4000, SP5500, SP5500+*, SP6000, SP6000+*, SP7000, SP7000+*, SP65, 1727, 1728, 1738
Magellan MG5000, MG5050, MG5050+*, MG5050E
DIGIPLEX EVO48, NE96, EVO96, EVO192*, EVOHD* (*Fw. 7.50 or above)
ESPRIT E55, 728ULT, 738ULT
Firmware PARADOX control panels, which are directly controlled, must be V.4 or higher.
* The serial port on the marked NEW alarm panels is factory-locked. Serial port unlocking must be performed to communicate with any external devices. How to unlock Serial Port
Magellan MG5000, MG5050, MG5050+*, MG5050E
DIGIPLEX EVO48, NE96, EVO96, EVO192*, EVOHD* (*Fw. 7.50 or above)
ESPRIT E55, 728ULT, 738ULT
Firmware PARADOX control panels, which are directly controlled, must be V.4 or higher.
* The serial port on the marked NEW alarm panels is factory-locked. Serial port unlocking must be performed to communicate with any external devices. How to unlock Serial Port
Data bus
PC585, PC1565, PC1616, PC1832, PC1864, PC1404, PC5015, PC5020
Data bus
NetworX (Caddx) NX-4v2, NX-6v2, NX-8v2, NX-8e
Serial port
Premier 24, 48, 88, 168, 412, 816, 832, 832+
Premier Elite 12, 24, 48, 64, 88, 168
Premier Elite 12, 24, 48, 64, 88, 168
Data bus
Inception
Data bus
Ademco Vista-15, Ademco Vista-20, Ademco Vista-48
Data bus
Runner 4/8, 8/16
Communication
Transmission Channel
Ethernet / LAN / IP communication IEEE802.3, 10 Base-T, port RJ45
Network configuration
DHCP or Manual
Connection with alarm control panel
TIP RING
Event reporting transmission channels
To main and backup receivers of up to 2 different security companies
To Protegus cloud, to iOS/Android Protegus mobile apps
To Protegus cloud, to iOS/Android Protegus mobile apps
Report transmission directions
2G (GPRS) or 4G
WiFi, LAN (with optional E485 module)
SMS or voice call
VHF / UHF radio signaling (with optional T16 communicator)
WiFi, LAN (with optional E485 module)
SMS or voice call
VHF / UHF radio signaling (with optional T16 communicator)
Transmission to remote monitoring
TCP / IP, UDP / IP
Transmission Protocol, Encryption
TRK, DC-09_2007, DC-09_2012, TL150
Event Transmission
Contact ID code
Event log / number of stored events
Yes, 100 events
Send periodic test reports
Yes
RS485
Yes
Compatible devices
Supported Modules
iO-8 Expansion Module - 8 terminal I / O
iO Expansion Module
iO-MOD - iO-WL radio transceiver expansion modules
iO Expansion Module
iO-MOD - iO-WL radio transceiver expansion modules
Max. number of RS485 modules
4
RS485 data bus length
up to 100m
Inputs
Inputs
2
Input types
NO, NC, EOL
Loop resistance
2.2kΩ
Outputs
Output (dedicated)
1
Control
Mobile app, browser
Programming
Programming modes
USB, IP
Programming Software
Yes, windows
Remote Programming
Yes
Users
Protegus users
Unlimited
Mobile Application
Yes
Web Application
Yes
Push notification
Yes
Limit Alerts
Yes
Technical data
Operating environment
-10°C - +50°C, relative humidity up to 80% + 20°C
Power supply
10-15V DC
Current consumption (nominal)
70 mA
Current consumption (max)
250 mA
Detachable terminal blocks
Yes
Size
88 x 62 x 26 mm
Weight
80g
PGM output
0.5A 30 VDC max.